Precast in Reinforced Concrete

Sewer Pit

Features and Operating Principle

The Spillway Pit has the specific function of controlling and distributing incoming water from sewer networks to specific treatments.
It can be sized to allow the separation and distribution of flow rates based on water levels; alternatively, upon request, spillway pits can be sized according to the flow rates to be distributed to each single discharge, providing partition baffles and thresholds with weirs calibrated according to specific needs.
In the case of storm water runoff treatment systems, the function of the spillway pit is to convey the first flush rainwater to the dedicated treatment and to bypass the second flush rainwater—defined by regulations as non-polluted—directly to the final receiver.
As this is a specific product tailored to the needs of individual cases and construction sites, the information provided is for indicative purposes only; sizing will be carried out by contacting the technical office based on the available information.

Supply Specifications

Supply and installation of a Spillway Pit produced in DECLARED SERIES, code SCOLM_-__ or SCOLM_-LAS__ of external dimensions cm.___x_____xh______ , produced by EDIL IMPIANTI 2 S.r.l. with management system UNI EN ISO 9001 and ISO 45001, made of Vibrato reinforced concrete, reinforced with vertical pillars and horizontal struts in stainless steel, with elastomeric protective anti-cracking paint Elastocolor of the external walls in permanent high elasticity and high chemical resistance concrete, concrete in the class of compressive strength C45/55 (RCK >55 N/mm 2), reinforced steel internal reinforcement with improved adhesion controlled in the factory and welded mesh type B450C square mesh, accompanied by certificates CHEMICAL RESISTANCE and FIRE REACTION (class: A1) issued by external body according to UNI EN standards.
The Scolmatore Well is supplied complete with:

  • n.1 entry point DN___ ;
  • n.1 exit hole DN___ ;
  • n.1 by-pass holeDN___ ;
  • Hydraulic sealed flow-control channel/channels (only in the SCOLM_-LAS___ );
  • Steel adjustable blades (only in the SCOLM_-LAS___ );
  • Steel grilling (on request).


View accessories related to the Specifications

Configure the Supply Specification with the related accessories.

Spillway Pit Dimensions

Download Technical Drawings

Select Article Code to access the Data Sheet for the product.

Article
Code
Drainage Chamber
External Dimension (cm)
Drainage Chamber
Weight (ql)
Cover slab
weight (ql)
Inspection
60x60 N.
Width Length Height h. 20 cm
(D400)
SCOLM0 100 100 100 10,7 5,0 1
SCOLM1 125 130 100 11,8 8,1 1
SCOLM2 125 130 130 14,2 8,1 1
SCOLM3 125 130 150 15,6 8,1 1
SCOLM4 175 180 150 23,8 15,6 1
SCOLM5 180 180 200 47,6 16,1 1
SCOLM6 246 220 200 68,4 26,9 1
SCOLM7 246 220 250 80,2 26,9 1

The data reported is purely indicative

Spillway Pit with R.C.V. Baffles and Steel Weirs Dimensions

Download Technical Drawings

Select Article Code to access the Data Sheet for the product.

Article
Code
Drainage Chamber
External Dimension (cm)
Drainage Chamber
Weight (ql)
Cover slab
weight (ql)
Inspection
60x60 N.
Width Length Height h. 20 cm
(D400)
SCOLM0-LAS 100 100 100 12,1 5,0 1
SCOLM1-LAS 125 130 100 13,6 8,1 1
SCOLM2-LAS 125 130 130 16,5 8,1 1
SCOLM3-LAS 125 130 150 18,3 8,1 1
SCOLM4-LAS 175 180 150 27,7 15,6 1
SCOLM5-LAS 180 180 200 55,7 16,1 1
SCOLM6-LAS 246 220 200 81,9 26,9 1
SCOLM7-LAS 246 220 250 97,2 26,9 1