Trivalent Anaerobic Percolator

Civil Wastewater Treatment

Trivalent Anaerobic Percolator

Imhoff Tank + Anaerobic Percolator Filter

Type C (Emilia Romagna - Friuli Venezia Giulia)
in precast concrete - complete with polypropylene Filter Media

Features and Operating Principle

The "Type C" Anaerobic Percolator Trivalent System (Imhoff Tank + "Type C" Anaerobic Percolator Filter) is a compact system designed to facilitate excavation, installation, and connection works.
The purification process for this type of natural wastewater treatment occurs through the combined action of sewage clarification (primary sedimentation and sludge digestion) taking place in the first stage (Imhoff Tank) and the degradation of organic matter occurring in the second stage (Anaerobic Percolator Filter) via the action of bacterial colonies that develop as films on suitable supports (polypropylene Filling Materials). The functions and characteristics of the anaerobic trickling compartment are the same as those described for the individual treatment on the previous pages.
It is a technological system with zero energy consumption.
The sizing of the trickling compartment includes a filter mass calculated using the formula S=N/H².

Filling Materials

Filling Materials
Shape: circular
Material: black isotactic polypropylene
Dimensions: about 170 mm
Specific surface: about 120 m²/m³
Vacuum index: about 95%
Dry weight: 32 kg/m³
Operating weight: about 350 kg/mc
Filling method: random

Download Project Type

Supply Specifications

Supply and installation of a "C" type Trivalent Anaerobic Percolator, CE marked and compliant with standards UNI EN 12566-1 and UNI EN 12566-3, produced in a DECLARED SERIES, code TRANC____ or TRANC-MK__ (Miniblock version) for N.____ P.E., composed of:
CE marked Imhoff tank dimensioned with 250 liters per P.E. and a "C" type Anaerobic Percolating Filter, CE marked with filter media (Filling Bodies) calculated according to the formula S=N/H², produced by EDIL IMPIANTI 2 S.r.l. with a UNI EN ISO 9001 and ISO 45001 management system, made of monoblock Vibrated Reinforced Concrete, reinforced with vertical pillars and horizontal tie rods in stainless steel, with Elastocolor protective anti-cracking elastomeric paint on the external concrete walls for high permanent elasticity and high chemical resistance, concrete in compression resistance class C45/55 (RCK >55 N/mm²), internal reinforcements in high-adherence steel controlled in the factory and B450C type square-mesh welded wire fabric, complete with CHEMICAL RESISTANCE and REACTION TO FIRE (class: A1) certifications issued by an external body in accordance with UNI EN standards.
The "C" type Anaerobic Percolating Trivalent system, CE marked, is supplied complete with:

  • CE marked Imhoff tank compartment dimensioned with 250 liters per P.E., complete with: inlet/outlet holes and relative PVC fittings positioned in the sedimentation compartment, vent impressions/holes placed laterally to the inlet hole, internal hoppers made of reinforced concrete to ensure the clear separation of the sedimentation/digestion chambers;
  • "C" type Anaerobic Percolator Filter CE marked with filter media (Filling Bodies) calculated according to the formula S=N/H², complete with: inlet/outlet holes, PVC inlet fitting and its relative PVC distribution channel, PVC collection channel and its relative PVC outlet fitting, polypropylene Filling Bodies.


View accessories related to the Specifications

Configure the Supply Specification with the related accessories.

Supply and installation of a "F/R" type Trivalent Anaerobic Percolator, CE marked and compliant with standards UNI EN 12566-1 and UNI EN 12566-3, produced in a DECLARED SERIES, code TRANFR____ or TRANFR-MK__ (Miniblock version) for N.____ P.E., composed of: 
CE marked Imhoff tank dimensioned with 200 liters per P.E. and a "F/R" type Anaerobic Percolating Filter, CE marked with filter media (Filling Bodies) calculated with 0.15 cubic meters per P.E., produced by EDIL IMPIANTI 2 S.r.l. with a UNI EN ISO 9001 and ISO 45001 management system, made of monoblock Vibrated Reinforced Concrete, reinforced with vertical pillars and horizontal tie rods in stainless steel, with Elastocolor protective anti-cracking elastomeric paint on the external concrete walls for high permanent elasticity and high chemical resistance, concrete in compression resistance class C45/55 (RCK >55 N/mm²), internal reinforcements in high-adherence steel controlled in the factory and B450C type square-mesh welded wire fabric, complete with CHEMICAL RESISTANCE and REACTION TO FIRE (class: A1) certifications issued by an external body in accordance with UNI EN standards.
The "F/R" type Anaerobic Percolating Trivalent system, CE marked, is supplied complete with:

  • CE marked Imhoff tank compartment dimensioned with 200 liters per P.E., complete with: inlet/outlet holes and relative PVC fittings positioned in the sedimentation compartment, vent impressions/holes placed laterally to the inlet hole, internal hoppers made of reinforced concrete to ensure the clear separation of the sedimentation/digestion chambers;
  • "F/R" type Anaerobic Percolator Filter CE marked with filter media (Filling Bodies) calculated with 0.15 cubic meters per P.E., complete with: inlet/outlet holes, PVC inlet fitting and its relative PVC distribution channel, PVC collection channel and its relative PVC outlet fitting, polypropylene Filling Bodies.


View accessories related to the Specifications

Configure the Supply Specification with the related accessories.

Regulations

Emilia Romagna Regional Resolution No. 1053/03,
Umbria Regional Council Resolution of May 7, 2019, No. 627,
Friuli Venezia Giulia Regional Guidelines L.G.40.02-E2 of 07/06/2019.

Technology

For every residential dwelling and production activity involving meal preparation and dishwashing, it is good practice to provide separate drainage lines for toilet waste (blackwater) from those for sinks, showers, bidets, washing machines, dishwashers, and glasswashers (greywater).
Blackwater must be conveyed directly into the Imhoff tank, while greywater containing oils, fats, and detergents must be conveyed first into a static grease trap and subsequently into the Imhoff tank or directly into the public sewer system if connected to a municipal treatment plant.

Fields of Application

Civil plants, slaughterhouses, cured meat factories, wineries, dairies, food industries, canning industries, pasta factories, confectionery products, fish industries, laundries and dry cleaners, residential housing, apartment buildings, restaurants, hotels, hospitals, communities, canteens, catering, schools, bars, campsites, bathing establishments, motorway service areas, meal production centers.

Sizing

SIZING FOR POPULATION EQUIVALENT CALCULATION
Sizing of Grease Traps and Imhoff Tanks, calculation of POPULATION EQUIVALENT (P.E.).
In residential dwellings as well as in production or service activities, it would be necessary to evaluate the actual sewage production to be disposed of in order to correctly size the Imhoff tanks. Since this is practically impossible, reference must be made to the number of Population Equivalents (P.E.), a standardized unit of measurement, which can be determined as follows:
Sizing of concrete Grease Traps and Imhoff Tanks for:
- RESIDENTIAL HOUSING - bedroom count:
1 P.E. for bedrooms with a surface area up to 13.90 sqm
2 P.E. for bedrooms with a surface area exceeding 14 sqm
Sizing of concrete Grease Traps and Imhoff Tanks for:
- HOTELS OR ACCOMMODATION FACILITIES - same as for residential housing;
add 1 P.E. for every 6 sqm increase in room surface area beyond the initial 14 sqm;
for holiday homes or special situations where seasonal use allows for high occupancy density, reference should be made to the maximum effective foreseeable potential.
Sizing of concrete Grease Traps and Imhoff Tanks for:
- FACTORIES OR ARTISAN WORKSHOPS
1 P.E. for every 2 employees, permanent or seasonal, during peak activity.
Sizing of concrete Grease Traps and Imhoff Tanks for:
- COMPANIES, COMMERCIAL OFFICES, SHOPS
1 P.E. for every 3 employees, permanent or seasonal, during peak activity.
Sizing of concrete Grease Traps and Imhoff Tanks for:
- RESTAURANTS AND TRATTORIAS - to calculate the population equivalent, it is necessary to quantify the maximum seating capacity of the dining rooms, considering that one person occupies approximately 1.20 sqm;
add the staff to the number of customers;
1 P.E. for every 3 people resulting from this calculation.
Sizing of concrete Grease Traps and Imhoff Tanks for:
- BARS, CLUBS, AND ASSOCIATIONS - same as the previous point but calculating 1 P.E. for every 7 people.
Sizing of concrete Grease Traps and Imhoff Tanks for:
- CINEMAS, STADIUMS, THEATRES - 1 P.E. corresponds to every thirty users.
Sizing of concrete Grease Traps and Imhoff Tanks for:
- SCHOOLS AND GYMS - 1 P.E. corresponds to every 10 attendees calculated on maximum potential. Special cases must be evaluated on a case-by-case basis (contact our technical office).
Note: After calculating the number of Population Equivalents, it is necessary to check with local competent authorities (A.R.P.A., Province, HERA) to determine the type of system to be installed.
The water supply to be calculated can vary from 100 L to 250 L for each Population Equivalent, based on local regulations and the type of activity.

"C" Type Trivalent Anaerobic Percolator Dimensions

Emilia Romagna - Friuli Venezia Giulia Region

Download Technical Drawings

Select Article Code to access the Data Sheet for the product.

Dimensioned Imhoff tank with 250 liters per A.E. and filter dimensioned with a filtering mass calculated using the formula S=N/H²


Article
Code
Population
Equivalent
(N)
Total
volume
(lt)
Imhoff Capacity (L) Anaerobic Percolator Filter External Dimensions
Anaerobic Trivalent (cm)
Tank Weight
(ql)
Cover slab weight (ql)
Sedimentation
Chamber
Digestion
Chamber
Filter Surface
(sqm)
Max. Height
(m)
Useful Volume
(cubic meters)
Width Length Height h. 10 cm
(B125)
h. 15 cm
(C250)
h. 20 cm
(D400)
TRANC-MK2B 1 2.600 250 200 1,00 1,0 1,00 120 220 150 37,0 7,0 10,0 13,0
TRANC-MK2C 2 3.700 250 400 0,89 1,5 1,33 120 220 205 47,0 7,0 10,0 13,0
TRANC-MK3C 4 4.700 250 800 1,78 1,5 2,67 120 270 205 55,0 8,0 12,0 16,0
TRANC01 5 6.000 250 1.000 2,22 1,5 3,33 180 220 200 63,8 9,8 14,8 19,7
TRANC02 6 7.500 300 1.200 2,67 1,5 4,00 180 270 200 73,1 12,1 18,1 24,1
TRANC03 7 9.000 350 1.400 3,11 1,5 4,67 180 320 200 82,1 14,3 21,5 28,6
TRANC03A 8 10,500 400 1.600 3,56 1,5 5,33 180 370 200 90,7 16,5 24,8 33,1
TRANC04AL 10 13.000 500 2.000 4,44 1,5 6,67 246 320 200 102,8 19,6 29,3 39,1
TRANC04BL 12 15.000 600 2.400 5,33 1,5 8,00 246 370 200 114,1 22,6 33,9 45,2
TRANC06 14 17.000 700 2.800 6,22 1,5 9,33 246 420 200 124,5 25,7 38,5 51,3
TRANC07 16 19.000 800 3.200 7,11 1,5 10,67 246 470 200 139,5 28,7 43,1 57,4
TRANC08 18 21.000 900 3.600 8,00 1,5 12,00 246 520 200 150,7 31,8 47,7 63,6
TRANC09 20 23.000 1.000 4.000 8,89 1,5 13,33 246 570 200 160,8 34,8 52,2 69,7
TRANC10 22 26.000 1.100 4.400 9,78 1,5 14,67 246 620 200 171,8 37,9 * 56,8 * 75,8 *
TRANC11 24 28.000 1.200 4.800 10,67 1,5 16,00 246 670 200 181,9 40,9 * 61,4 * 81,9 *
TRANC12 25 30.000 1.250 5.000 11,11 1,5 16,67 246 720 200 197,5 44,0 * 66,0 * 88,0 *
TRANC13 27 32.000 1.350 5.400 12,00 1,5 18,00 246 770 200 207,8 47,1 * 70,6 * 94,1 *
TRANC14 29 34.000 1.450 5.800 12,89 1,5 19,33 246 820 200 218,6 50,1 * 75,2 * 100,2 *
TRANC15 31 36.000 1.550 6.200 13,78 1,5 20,67 246 870 200 229,3 53,2 * 79,7 * 106,3*
TRANC16 33 38.000 1.650 6.600 14,67 1,5 22,00 246 920 200 240,0 56,2 * 84,3 * 112,4*
TRANC17 34 40.000 1.700 6.800 15,11 1,5 22,67 246 970 200 255,3 59,3 * 88,9 * 118,5 *
TRANC18 36 42.000 1.800 7.200 16,00 1,5 24,00 246 1020 200 265,5 62,3 * 93,5 * 124,7 *
TRANC19 40 44.000 2.000 8.000 17,78 1,5 26,67 246 1070 200 276,6 65,4 * 98,1 * 130,8 *

* Cover Slab divided into two parts
The data reported is purely indicative

"F/R" Type Trivalent Anaerobic Percolator Dimensions

Download Technical Drawings

Select Article Code to access the Data Sheet for the product.

Imhoff tank dimensioned with 200 liters per A.E. and filter dimensioned with a filtering mass calculated with 0.15 cubic meters per A.E.


Article
Code
Population
Equivalent
(N)
Total
volume
(lt)
Imhoff Capacity (L) Anaerobic Percolator Filter External Dimensions
Anaerobic Trivalent (cm)
Tank Weight
(ql)
Cover slab weight (ql)
Sedimentation
Chamber
Digestion
Chamber
Max. Height
(m)
Useful Volume
(cubic meters)
Width Length Height h. 10 cm
(B125)
h. 15 cm
(C250)
h. 20 cm
(D400)
TRANFR-MK3B 6 3.300 300 900 1,0 0,90 120 270 150 44,0 8,0 12,0 16,0
TRANFR-MK4B 8 4.000 400 1.200 1,0 1,20 120 320 150 49,0 10,0 14,0 19,0
TRANFR11 11 5.500 550 1.650 1,0 1,65 180 270 150 58,8 12,1 18,1 24,1
TRANFR13 13 6.500 650 1.950 1,0 1,95 180 320 150 66,7 14,3 21,5 28,6
TRANFR16 16 7.500 800 2.400 1,5 2,40 180 270 200 72,1 12,1 18,1 24,1
TRANFR19 19 9.000 950 2.850 1,5 2,85 180 320 200 81,2 14,3 21,5 28,6
TRANFR23 23 10.500 1.150 3.450 1,5 3,45 180 370 200 90,4 16,5 24,8 33,1